Ground vibration
Follow vibrations from ground to building
Use the VM-56 for measurements during construction, demolition and traffic. Register vibrations in three axes simultaneously and see both peak value and frequency content when events need to be documented.
Control during construction work
Place the sensor at the relevant measuring point and follow events from, for example, impact or compression.
PPV and dominant frequency
Compare the peak value of the particle velocity with a frequency-dependent assessment criterion. RION states that the comparator supports i.a. criteria according to DIN 4150-3.
Monitoring over time
Log data to SD card for post-processing. Remote monitoring can be configured as a separate solution.
Measurement data and analysis
The VM-56 calculates PPV, dominant frequency, VDV and offset. Measurement results are saved as CSV. The acquisition program VX-56WR provides raw signal recording as WAV, and VX-56RT provides ⅓-octave analysis.
Key technical data
RION specifies DIN 45669-1 for measurement and frequency range. See the data sheet for measurement ranges, weightings and other conditions.
Delivery and documentation
Standard delivery according to the data sheet includes the PV-83D, batteries, case, SD card and calibration certificate. Clarify assembly and any add-on programs when making an offer.
Get an offer for your measurement setup
Describe the vibration source, the measurement point, the measurement period and the criteria you must report on. We help with sensor placement, logging and choice of configuration.
Project monitoring with alarms and remote access
See vibration equipment · Service and calibration · Are you measuring hand-arm or whole-body vibration? See MMF VM100A